16

Multimode Port Specifications (All Models)

Table 10 Fiber Optic Transmitter

Table 11 Fiber Optic Receiver

Table 12 Fiber Optic Datalink

Fiber Type

1

1. MMF = Multimode Fiber

Fiber Optic

Diameter

(microns)

Optical

Frequency

Launch Power (dBm)

2

2. Launch power measured at one meter from the transmitter.

Maximum

Average

Minimum

MMF

50/125 1310

nm

-14.0

-20.3

-22.5

MMF

62.5/125

1310 nm

-14.0

-16.8

-19.0

Fiber Type

1

1. MMF = Multimode Fiber

Fiber Optic

Diameter

(microns)

Optical

Frequency

Receive Power (dBm)

Minimum

Typical

Saturation

MMF

50/125

1310 nm

-31.8

-34.5

-14.0

MMF

62.5/125

1310 nm

-31.8

-34.5

-14.0

Fiber

Type

1

1. MMF = Multimode Fiber

Fiber
Optic

Diameter

(microns)

Optical

Frequency

Minimum

Power/

Link

Budget

(dB)

Average

Signal

Loss (dB)

Minimum

Distance

Specs

2

2. In all cases where the maximum transmitter output power exceeds the receivers sensitivity, a recommended

minimum ranges is stated. This is to prevent blinding or burning out the optical receiver on the far-end
node.

Maximum

Distance

Specs

(Full-duplex

only)

MMF

50/125

1310 nm

13.00

18.70

0

2 km (1.2 mi)

MMF

62.5/125

1310 nm

16.80

22.50

0

2 km (1.2 mi)

Advertising