Installation – Blodgett 40ES-KLT Series User Manual

Page 8

Advertising
background image

6

OM-40ES-KLT

The kettle is provided with complete internal wiring and is ready for immediate

connection. Wiring diagrams are provided in this manual and on the inside of the

control housing service panel. Any mechanical or electrical changes must be approved

by the Food Service Engineering Department.

The completed unit has been operated at the factory to test all controls and heater

elements.

1. Set the kettle in place and level it by turning the bullet feet to adjust leg

length. Allow clearance around the unit for cleaning, maintenance and

service.

2. Confirm that the jacket water level is at the mid point of sight glass. If the

level is low, follow the instructions under “Jacket Filling and Water

Treatment,” Page 14.

3. The open end of the elbow on the outlet of the pressure relief valve must face

downward. If it does not, turn it to the correct position.

4. Provide electrical power specified on the equipment electrical information

plate. Observe local codes an/or The National Electrical Code in accordance

with ANSI/NFPA 70 - (current edition.).

5. The equipment is shipped ready for three phase operation. Refer to the wiring

diagram for single phase operation.

6. Bringing the electrical service through the entrance at the rear of the support

housing with one inch conduit, making a watertight connection with the

incoming lines. Observe local codes and/or the National Electrical Code

in compliance with ANSI/NFPA 70 (latest edition). When there is a choice

between applicable codes, we recommend following the more stringent

code. (A BX connection is not recommended.)

7. Electrically ground the unit at the terminal provided.

8. Check the following to confirm that your kettle is properly installed:

Room for cleaning and servicing

The kettle is level

The correct amount of water is in the kettle jacket

Pressure relief valve is pointed down

Unit is connected with a waterproof supply of the proper voltage, phase

and amperage rating

ELECTRICAL SPECIFICATIONS*

Voltage

kW

Amperes

208V

21

59

240V

24

61

480V

24

29

400V

24

35

* All at 3-phase. Single-phase also available.

WARNING

DO NOT CONNECT ANY PIPING TO THE

PRESSURE RELIEF VALVE. THE VALVE MUST
BE FREE TO VENT STEAM AS NEEDED.

IMPROPER INSTALLATION WILL VOID THE

WARRANTY! THE ELBOW ATTACHED TO

THE SAFETY VALVE MUST

POINT TO THE FLOOR.

Installation

WARNING

INSTALLATION OF THE KETTLE MUST

BE DONE BY PERSONNEL QUALIFIED TO

WORK WITH ELECTRICITY. IMPROPER

INSTALLATION CAN RESULT IN INJURY TO

PERSONNEL AND/OR DAMAGE TO

EQUIPMENT.

DANGER

ELECTRICALLY GROUND THE UNIT AT THE

TERMINAL PROVIDED. FAILURE TO GROUND

UNIT COULD RESULT IN

ELECTROCUTION AND DEATH.