Installation – Blodgett KTC-E Series User Manual

Page 9

Advertising
background image

OM-KTT/KTC-E 7

KTT/KTC SUPPLY WIRE REQUIREMENTS

THWN (75°) / THHN (90°) COPPER ONLY

5E/6E-KTT, 5E/6E-KTC

10E/12E-KTT, 10E/12E-KTC

VOLTAGE

AMPS

SUPPLY

WIRE

VOLTAGE

AMPS

SUPPLY

WIRE

208V 1 PH

3 PH

31
18

8

12

208V 1 PH

3 PH

52
30

6
8

240V 1 PH

3 PH

35
20

8

12

240V 1 PH

3 PH

60
35

4
8

460V 3 PH

7.3

14

460V 3 PH

14

12

480V 1 PH

3 PH

14

8

14
14

480V 1 PH

3 PH

25
15

10
12

c.

For conversion from 480V, 3-phase to 460V, 3-phase:

i.

Verify that the branch circuit wiring is adequate for any

increase amperage requirements (see table on page 8).

ii.

Complete “conversion label” (supplied in bag and adhere it

to the control box near the UL dataplate).

5.

Bring incoming electrical service through the conduit fitting (for 240V

1-phase, a new one inch conduit fitting is required) at the rear of the support

housing, making a watertight connection with the incoming lines. A BX style

connection is not recommended.

6.

Confirm that the jacket water level is at or just above mid point of sight glass

(new models). If the level is low, follow the instructions under “Jacket Filling

and Water Treatment” in the “Maintenance” section of the manual.

7.

Ensure that the open end of the elbow on the outlet of the pressure relief

valve is directed downward.

DANGER

ELECTRICALLY GROUND THE UNIT AT

THE TERMINAL PROVIDED. FAILURE TO

GROUND UNIT COULD RESULT IN

ELECTROCUTION AND DEATH.

Installation

Pull lead from 208V tab and insert on 240V tab.

Advertising
This manual is related to the following products: