1.0 INSTALLATION INSTRUCTIONS

The appliance must be installed in accordance with:

1. State and/or local codes.

2. In the USA, the National Electrical Code, ANSI/NFPA-70 (Latest Edition). In Canada, the

Canadian Electrical Code, Part 1, CSA standard C22.1 (Latest Edition)


INSTALLATION

1. Select a location to provide drainage directly below the pour path. Allow sufficient rear

clearance from wall for kettle to tilt freely and completely without obstruction.


2. Mark hole locations through flanged adjustable feet. Remove feet.

3. On hole locations marked, drill holes and insert expansion shields to accommodate 5/16" size

lag bolts.


4. Reposition kettle. Level kettle by making necessary adjustments on flanged feet.

5. Bolt down kettle and seal with Silastic or other equivalent sealing compound. Sealant must

be applied not only to bolt heads but also around flanges making contact with floor surface to
fulfill NSF International requirements. Wipe off excess sealant immediately.


6. A control box with power supply equivalent to electrical rating of kettle should be located

conveniently nearby.


7. A waterproof electrical connection from power supply to rear of control housing must be

provided.


8. Ground kettle to terminal provided inside control housing.

9. Turn power ON and check for proper operation.