Swiftech MCW6000 2 P User Manual

Page 2

Advertising
background image




3. Water-block

installation

Step 1



Step 2





Step 3

Center the water-block inside the retention
frame. Put both clips in place for the next
step, by simply slipping the hook of each
clip into the holes of the retention frame.

While maintaining the opposite side of the
block to prevent it from tipping over, push
down on the clips’ thumb-tab until the hook
catches the hole in the retention frame.

Keep maintaining pressure on the block to
prevent it from tipping over, and hook-
down the second clip.
Installation is complete!

Tubes attached with the included
worm-drive clamps

4.

Connecting the water-block(s) to the cooling circuit:

Carefully identify the direction of the flow in your circuit. For the MCW6000 to operate
properly, the fitting located at the center of the water-block MUST BE USED AS THE INLET.

5.

Attaching the tubes:


The MCW6000™ series ship with worm-drive type hose clamps. Secure the tubes as shown
in the picture to the right (shown below with an AMD bracket), and tighten firmly.


6. Type

of

Coolant:


Being entirely made of copper, the MCW6000™ series may be used with pure water, and do
not necessitate the use of anti-corrosion agents. The use of an algaecide is nonetheless
recommended in any liquid cooling system, and our HydrX™ additive also performs such
function.

7. Final

inspection


Once the installation is completed, it is always a good idea to test the circuit for leaks, prior to
powering up the computer. Do not test the water-block using city water pressure. This
will bow the top of the housing and render the block unusable (and will void your warranty).
Maximum pressure allowable for testing is 25 psi (1.7 bar)

Troubleshooting help is available on our web site at

www.swiftnets.com

, or by calling

customer support at 562-595-8009.


IMPORTANT DISCLOSURES
While all efforts have been made to provide the most comprehensive tutorial possible, Swiftech assumes no liability
expressed or implied for any damage(s) occurring to your components as a result of using Swiftech cooling products,
either due to mistake or omission on our part in the above instructions, or due to failure or defect in the Swiftech cooling
products.
WARRANTY
Our products are guaranteed for 12 months from the date of delivery to the final user against defects in materials or
workmanship. During this period, they will be repaired or have parts replaced provided that: (I) the product is returned to
the agent from which it was purchased; (II) the product has been purchased by the end user and not used for hire
purposes; (III) the product has not been misused, handled carelessly, or other than in accordance with any instructions
provided with respect to its use. This guarantee does not confer rights other than those expressly set out above and
does not cover any claims for consequential loss or damage. This guarantee is offered as an extra benefit and does not
affect your statutory rights as a consumer.

Copyright Swiftech 2004 – All rights reserved – Last revision date: 11-23-04
Rouchon Industries, Inc., dba Swiftech – 1703 E. 28

th

Street, Signal Hill, CA 90755 – Tel. 562-595-8009 – Fax 562-595-8769 - E

Mail: [email protected] – URL:

http://www.swiftnets.com

- Information subject to change without notice

Advertising