AquaStar 125X User Manual

Page 6

Advertising
background image

1.

The ECO is mounted on the lower left
outlet water pipe.
(See figure C)

a. Remove one lead connecting to ECO
terminal, it does not matter which one is
disconnected.
b. Attach 1/4" quick connect terminal end of
linear spill switch cable to now exposed
terminal of the ECO.
c. Remove the eyelet ended terminal from
the other spill switch cable. Affix the push on
male spade connector, which is provided with
the AQ1, to this spill switch cable.
d. Connect this male spade connector to the
removed lead wire from step 3.a.

The linear spill switch should be attached to the upper
right-hand side on the draft hood diverter (see figure D),
on the Model 425HN and 125HX the linear spill switch
should be attached to the upper left-hand side of the
draft hood diverter. There are two holes provided for
attachment on this diverter and only the front most hole
should need to be used. With the provided #12 self
tapping sheet metal screw securely mount the spill
switch bracket to the diverter. For ease of access
position it so the reset button faces outward and then
bend the bracket so the switch can stand vertically.

The copper capillary sensing tube should then be di-
rected to the opposite end of the draft hood diverter, by
laying it in front of the 5" diameter vent pipe opening, and
down the other side of the draft hood diverter.

DISCONNECT

EITHER

WIRE

FROM

ECO

TERMINALS

ON

HOT

WATER

PIPE

.

PUSH

ON

ONE

SPILL

SWITCH

LEAD

CABLE

TO

ECO

AND

OTHER

(

RETROFIT

FIRST

)

INTO

EITHER

WIRE

THAT

WAS

REMOVED

.

ECO

F

IGURE

C

F

IGURE

D

CAPILLARY

SENSING

TUBE

SPILL

SWITCH

CABLES

RESET

BUTTON

5

NOTE: ON

THE

MODEL

425HN

AND

125HX,

REVERSE

THE

DIRECTION

OF

THE

CAPILLARY

SENSING

TUBE

SO

THE

RESET

BUTTON

ASSEMBLY

IS

ATTACHED

TO

THE

UPPER

LEFT

-

HAND

SIDE

OF

THE

DRAFT

HOOD

DIVERTER

.

ECO

HOT

WATER

PIPE

Advertising
This manual is related to the following products: