Specifications and Dimensions
F232228
28
UWAV Pocket Hardmount
Electrical Specifications
Voltage Designation
Standard
Mode
l
Code
Vo
lt
a
g
e
Cy
c
le
Ph
ase
Wi
re
Full
Load
Amps
Bre
ake
r
AW
G
mm
2
35
N
440-480
50-60
3
3
4
15
14
3x2.5
P
380-415
50-60
3
3
4
15
14
3x2.5
X
200-240
50-60
1/3
2/3
9
15
14
2/3x2.5
60
N
440-480
50-60
3
3
4
15
14
3x2.5
P
380-415
50-60
3
3
4
15
14
3x2.5
X
200-240
50-60
1/3
2/3
10
15
14
2/3x2.5
80
N
440-480
50-60
3
3
6
15
14
3x2.5
P
380-415
50-60
3
3
6
15
14
3x2.5
Q
200-240
50-60
3
3
9
25
14
3x6
100
N
440-480
50-60
3
3
6
15
14
3x2.5
P
380-415
50-60
3
3
6
15
14
3x2.5
Q
200-240
50-60
3
3
10
25
10
3x6
125
N
440-480
50-60
3
3
7
15
14
3x6
P
380-415
50-60
3
3
7
15
14
3x6
Q
200-240
50-60
3
3
13
25
10
3x6
Note: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.