4 osc filter section – Akai UNIQUEST 4000S User Manual

Page 20

Advertising
background image

A Quick Tour of UniQuest For EWI 4000s

20

of

44

UniQuest for EWI 4000s

2.2.4

OSC FILTER SECTION

SELECT

Choices are 1, 2 or LINK. When 1 is selected, the block of controls in this
section govern the settings of OSC FILTER 1. When 2 is selected, these controls
govern the settings of OSC FILTER 2. LINK mode is now explained.

The Oscillator Filter section consists of 2 multi-mode filters that are connected in
serial with each other. Each filter can be set individually or can be linked to realize a
double-strength filter whose parameters are set by filter 1’s controls:

The following parameters are common to each filter:

Main Filter Parameters

MODE

This control changes the filter’s basic type:

OFF: Filter is off, incoming signals are passed unchanged.

NTC: Notch - Removes a band of signal content around the filter cutoff
frequency. This signal is therefore ‘notched’.

BP: Band Pass - Removes signal content except for a band around the filter cut-
off frequncy. This band is allowed to pass unchanged.

HP: High Pass - Removes signal content below the filter cutoff frequency. High
frequencies are allowed to pass unchanged.

LP: Low Pass - Removes signal content above the filter cutoff frequency. Low
frequencies are allowed to pass unchanged.

FREQ

Range is 65.5 Hz to 10.5 kHz. This control sets the cutoff frequency of the OSC
FILTER.