6.6"

(168mm)

Allow 3" (76mm) below

cartridges for replacement.

26"

(660mm)

BWS BLENDED WATER SYSTEM

ITEM FI-28727

W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 • U.S.A.

phone

: 262.251.3800 800.558.8744

u

.

s

.

a

./

canada

fax

: 262.251.7067 800.329.8744

u

.

s

.

a

.

only

website

: www.alto-shaam.com

printed

in

u

.

s

.

a

#465 - 05/10

due

to

ongoing

product

improvement

,

specifications

are

subject

to

change

without

notice

.

It is recommended that PreFilters be changed

every 3-6 months, when capacity is reached

or when inlet water pressure or flow becomes

inadequate. Change the ScaleX2

®

cartridge

annually. Membrane life varies depending on

inlet water conditions and PreFilter maintenance.

12-18 months under typical conditions but it can

be as long as 3-5 years.

This product is for commercial use only and

must be installed and maintained according to

manufacturers guidelines.

Do not use on water that is microbiologically

unsafe or of unknown quality without adequate

disinfection before or after the system.

INLET WATER CHEMISTRY

Feed TDS

Up to 1200 ppm Iron

0.1 mg/l max

Feed pH

6-10

Turbidity

0.05 NTU

Hardness*

28 grains or less Manganese 0.05 mg/l max

Free Chlorine <2 mg/l

Hydrogen

Sulfide

0.0 mg/l

* For water outside of these parameters call technical service.

SYSTEM
Dimensions - Processor Tank

(

h

x

w

x

d

)

30.5" x 26" x 6.6"

(775mm x 660mm x 168mm)

41" x 24"dia.

(1,041mm x 610mm)

Inlet Water Connection

3/8” Push Fit Tubing

Operating Pressure Range

50-85 psi at 1 gpm (3.5 - 5.9 bar)

Inlet Water Temperature Range

40º - 100º F (4º - 38º C)

Shipping Weight

100 lbs. (45kg)

Power Requirements

(Within 5' of unit)

Processor

RP Pump

120V 15A circuit

120V 15A circuit

Drain Connection

(Within 5' of unit)

2 GPM Minimum Flow

PERFORMANCE
Typical TDS* Rejection

97+%

Product Water Production (at 77ºF, 60psi)

Production rate is strictly dependent on feed

water temperature and pressure.

350 gals (1325L)/day

14.6 gals (55L)/hr

0.25 gpm

Blended Water Production

Up to 400 GPD

Repressurization Pump (Self-priming)

0.25-2.75gpm at 50 psi

ACCESSORIES
Replacement Filter cartridge AMS-QT

FI-29316

Replacement Filter cartridge SCLX2-Q

FI-29317

Replacement

PreFilter

Filter cartridge CTO-Q

FI-29318

INSTALLATION REQUIREMENTS

Connection to system should be

to the cold water inlet only.

Do not exceed system specifications for

temperature and pressure.

Provide a dedicated 3/4" water line to the unit to

consistent flow and pressure to the system.

Allow 3" (76mm) clearance below system for filter

cartridge removal and replacement.

Connect filtered water line to steam production

connections only. Do not use for condenser water.

Detailed installation, operation & maintenance

manual is included with each system.

Mount the BWS-QT processor where the Water

Quality Monitor and ByPass Valve can be easily

viewed and accessed.