Electrical connection – Indesit KD6G35 – Dual Fuel User Manual

Page 17

Advertising
background image

17

GB

WARNING - THIS APPLIANCE MUST BE EARTHED.

The cooker must be connected by a qualified

electrician to a suitable double - pole control unit

with a minimum rating of 32A and a minimum

contact clearance of 3mm, which should be fitted

adjacent to (but not above) the cooker, in

accordance with IEE regulations.

The power supply cable should conform to BS6004

with a conductor size of 4mm

2

.

The control unit should be easily accessible in the

event of an emergency.

This appliance conforms to EN55014 regarding

suppression of radio and television interference.

The cooker terminals are behind the cover at the rear

The mains cable must pass through the cable clamp

and the screws must be fully tightened. Sufficient

cable should be used to allow the cooker to be

pulled out for servicing. Ensure that the cover is fully

closed and secure afterwards.

Take care not to trap the mains cable when pushing

the cooker into its final position.

Electrical Connection

OP-RATIONAL +H-+KS

After installation, check for gas soundness.

The supply pressure can be checked at one of the

hotplate burner injectors.

Check that the hotplate burners ignite correctly and

burn with a steady flame.

Check for a steady flame at the low setting.

Instruct the user on the operation of the cooker.