The electrical connection to the mains must be made on

the appliance. The power voltage and frequency are as

indicated on the rating plate.

! THIS APPLIANCE MUST BE EARTHED.

Fitting the power supply cable

1. Open the terminal board

by inserting a screwdriver

into the side tabs of the

cover. Use the screwdriver

as a lever by pushing it

down to open the cover (see

diagram)

.

2. Install the power supply

cable by loosening the

cable clamp screw and the

three wire contact screws
L-N-

.

Connect the wires to the

corresponding terminals:

the Blue wire to the terminal

marked (N), the Brown wire

to the terminal marked (L)

and the Yellow/Green wire
to the terminal marked

(see diagram).

3. Secure the cable by fastening the clamp screw.

4. Close the cover of the terminal board.

Electrical Connection:

Voltage Frequency: see data plate

Fuse Section: 16A

Supply cable: 3x1.5mm

2

You can connect your oven to the system means of a

terminal board. Refer to above information for the minimal

cable sections and the calibration of the protective elements

according to the connection.

If the appliance is installed with a junction box, an

omnipolar circuit breaker

- with a minimum contact

opening of 3mm - should be installed between the appliance

and the mains.

Power cable supply connection to the electrical mains:

We recommend you use a power supply cable which is

long enough to allow you to take the oven out of its recess

in the event of maintenance operations (only use HAR - H

05 - RRF quality cables fitted with a plug conforming to the

regulations in force.

The plug must be accessible at all times.

N

L

Unplug the appliance before all operations, even

when replacing the oven lamp.

Using the appliance without correct earthing is highly

dangerous.

! After connecting the appliance to the flexible cable,

tighten all the screws on the terminal board.

APPLIANCE SPECIFICATIONS

Dimensions*

width 43.5 cm

height 32,4 cm

depth 40.3 cm

Volume*

57 l

Dimensions**

width 45.5 cm

height 32,4 cm

depth 40.3 cm

Volume**

60 l

Electrical

connections

voltage: 230-240V~ 50/60 Hz

maximum power absorbed

2800-3000 W

* Only for models with drawn rails.

** Only for models with wire rails.

ENERGY

LABEL

Directive 2002/40/EC on the label of

electric ovens. Standard EN 50304

Energy consumption for Natural

convection – heating mode:

Traditional mode

Declared energy consumption for

Forced convection Class – heating

mode: Baking

This appliance conforms to the

following European Economic

Community directives: 2006/95/EEC

dated 12/12/06 (Low Voltage) and

subsequent amendments –

2004/108/EEC dated 03/05/89

(Electromagnetic Compatibility) and

subsequent amendments -

93/68/EEC dated 22/07/93 and

subsequent amendments.

2002/96/EC and subsequent

amendments.

- 1275/2008 standby/off mode