The equipment can function independent of the

mains for approx. 2.5 hours with a fully charged
battery.
New batteries reach their full capacity after 4-5
charge and discharge cycles. Batteries which have
not been used for a long time should be recharged

before use.
Temperatures in excess of 50°C reduce the
battery's performance. Avoid long periods of
exposure to sunor heat.

Operating controls/displays

B

Rotary ON/OFF knob:

Device on/off,
Lighting control
- Output video signal
= Input video signal

Battery-charge- warning-lamp

red -> fast charge

green -> float charging

Metre counter (optional): overlay of distance
already travelled by camera on monitor. Reading
can be forwards or backwards. Can be zeroed at
any point with the reset button.

During initialisation immediately after
switching
on there may, in certain circumstances, be
indeterminate
inserts. If this is the case, switch off the

equipment and wait for approx. 5 seconds
before switching it back on.

chi

Changing the battery

C

Insert battery in the fixture on the rear until it

latches into place. To remove, press both catches
and extract battery.

Connecting recording equipment

D

Tube inspections can be documented with external
recording equipment.
Videorekorder mittels Scartkabel anschließen.

During recording "button

" in position -.

During playback via the ROCAM® screen display

"button

" in Position =.

Connect computer by means of USB cable..

During recording"button

" in position -.

Cleaning E

It is essential to clean the equipment after every
tube inspection.
Switch off the equipment, remove the battery and,
where applicable, disconnect the power supply
unit.

Close the cover ensuring that it locks into place.
Clean the reel cable on the base with water (spray
jet).Clean the camera head with water (spray jet)
before inserting it into the bracket.

Never aim the jet of water at the front of
the

quipment (display screen/control panel).

Operating the equipment

F

Clean the tube system before inspecting the tubes.
1

Press the button and open the cover,
ensuring that it locks into place.

2

Switch on the equipment using the rotary
button.

Switch on the display screen using the
"POWER"button.

3

Remove the camera head from the bracket
and uncoil the reel cable from the reel.

The reel cable is rigid and under mechanical
stress.
Therefore hold the reel cable tight when
uncoiling it from the reel!

4

Insert the camera head in the tube system
and feed it in carefully with the reel cable.

Do not kink the reel cable or pull it over
sharp edges!

Wear protective gloves!

Always stand beside the reel
cable!

For tube ø greater than 80 mm mount the guide
pieces. The guide pieces can be adjusted to the
tube ø by cutting off the margins.

The reel cable can form loops while being

fed in constituting a risk of fracture!
The camera picture can turn upside down
while being fed through several bends in the
tube – this is a normal occurrence and does
not mean that the system is defective.

Upon completion of work pull the reel cable out of
the tube and roll it directly onto the reel.
Clean the camera head under flowing water (spray
jet – not pressure jet)
Replace camera head in bracket.
Close cover. Display screen switches off
automatically.