ROTHENBERGER ROWELD Quick S komplett User Manual

Page 10

Advertising
background image

8

ENGLISH

Service

Never have your device repaired by anyone but

qualified personnel and always use original spare
parts. This will ensure that the safety of the device
is maintained.
Only authorized personnel should exchange fuses
or perform repairs. Please contact the address

shown below.

Intended

Use

This hot air device is intended for all the hot air
applications listed in this operating manual; always
observe the safety regulations and only use original
accessories with it.
Applications A:
- Welding of thermoplastics and elastomere

bitumen

- Shrinking of heat-shrinkable tubing, foil

packaging

- Warming up thermoplastic semi-finished goods

for purpose of forming

- Drying of watery wet surfaces

- Unthawing of frozen water pipes

- Removing old shellac varnish, synthetic enamel

- Activating and dissolving adhesives and hotmelt

type adhesives which do not contain any solvents

Applications B:
- Industrial assembly work

- Drying and heating up processes of all kinds

- Activating and dissolving adhesives and hotmelt

type adhesives which do not contain any solvents

- Heat-shrinking and welding of foil packaging

and preforms

- Separating and fusing together synthetic threads

and textiles

- Sterilizing packaging materials

- Removing plastic flashing and finish-polishing

plastic surfaces

The device is not suitable to be used in an explosive
atmosphere!

Touching hot jets or reflectors can lead to serious

burns. Before assembling or changing jets or
reflections, allow the device to cool down
completely or use suitable tools. The jets and

reflectors must be mounted firmly and safely onto

the device.

Hot jets and reflectors can ignite items or the base
of the device. Always ensure you only set down
hot jets and reflectors on a fire-resistant base.

Incorrect or damaged jets can cause a blockage of

hot air and damage the device. Use only original
jets or reflectors!

Device

elements

A

1 Heating element pipe

2 Rubber stand

3 Handle

4 Mains connection lead

5 Mains outlet

6 Potentiometer for setting temperature

Mounting and firm installation

The device is intended for installation in machinery
and equipment and is designed for continuous
operation.
Please ensure the following points when installing:
- that only cold air is supplied

- that no heat blockage can develop

- vibrations and jarring that the device is protected

against mechanical

- that other sources of hot air do not blow on the

device

Commissioning

Check mains connection lead and plug for
mechanical damages!
Observe the mains voltage! The mains voltage

must coincide with the details on the rating plate.
Activation:
Set the mains switch 5 to position 1. Adjust the
temperature using the potentiometer 6, if
necessary. The warm-up time for the device is
approx 5 minutes.
De-activation:
Turn the potentiometer 6 to position 0 for cooling
down. Once the unit has cooled down, set the
switch 5 to 0.