Vzn series, Installation (continued) – A.J. Antunes & Co VZN-441H 9700740 User Manual

Page 14

Advertising
background image

VZN SERIES

14

P/N 1011047 Rev. F 12/13

INSTALLATION (continued)

Sanitizing the System and Lines

The plumbing must be sanitized to eliminate possible contam-

ination that may have occurred during the installation process.
One ounce (30 ml) of liquid chlorine bleach (regular bleach,

unscented 5.25 % - 6 % sodium hypochlorite) or Kay-5

sanitizer solution (Sodium Dichloro-s-Triazinetrione Dihydrate,

6%) or equivalent can be used to sanitize the plumbing.
The Kay-5 sanitizer solution is made by dissolving a 1 oz.

packet of Kay-5 powder in 2 oz. (60 ml) of clean warm water.

This can be done by removing 1 inch from the top of the

Kay-5 packet and adding the 2 oz. of warm water to the pack-

et. Mix with a coffee stirrer to dissolve. When added to the

system, this will create a 60-100 ppm chlorine solution.
NOTE: Follow the handling and safety instructions

supplied with the bleach.
NOTE: If installed, remove the Carbon Element from the

system BEFORE Sanitizing.

1. Follow the steps in the

Rinsing the Ultra Filter

Cartridge in the Installation section of this manual.

2. Turn off the water to the system.

3. Open the faucet or tap closest downstream to the

system.

4. Allow the system and plumbing to drain.

5. If an inlet sanitation fitting is installed, remove the plug

or disconnect the water line at the inlet of the system.

Allow the water to drain out of the system.

6. Pour the sanitizer into the inlet sanitation fitting or inlet

water line using a cup or funnel. Be careful not to spill

bleach onto clothing or skin.

7. Reattach the plug on the sanitation fitting.

8. Slowly turn on the water supply to the system.

9. Allow water to flow through the system and out of the

open faucet or tap until the smell of bleach is present.

10. Close the faucet or tap.

11. Let the system stand without water flow for at least 15

minutes to allow the bleach to sanitize the pipes.

12. After 15 minutes without water flow, open the faucet or

tap.

13. Allow water to flow through the system until the

presence of bleach is gone.

14. Open all other faucets and taps in line with the system

to flush any remaining bleach from the plumbing.

15. Close all faucets and taps.

Rinsing the Carbon Element

The Carbon Element MUST be rinsed before using the sys-

tem the first time and immediately after the Carbon Element

has been replaced.

1. Install the Carbon Element into the Carbon Element

Housing.

2. Screw the Carbon Element Housing (containing the

Carbon Element) into place on the Carbon Element

Head. The Housing will come to a hard stop at the end

of the thread. Use a Filter Wrench if necessary.

NOTE: Do NOT overtighten the Carbon Element Housing.

3. Direct water from the Rinse Ball Valve to a drain.

4. Then open the Rinse Ball Valve and close the Outlet

Ball Valve.

5. Turn on the water to the system by slowly opening the

Inlet Ball Valve.

6. Allow water to flow through the Carbon Element

Housing to flush out trapped air and any debris that

may be present.

7. To help remove trapped air from the Housings, press

the RED Pressure Relief Button on the top of the hous-

ings until water just begins to come out.

8. Flush the Carbon Element for at least 5 minutes.

NOTE: Do NOT consume water used during this process.

9. When the rinsing is complete, close the Rinse Ball

Valve and open the Outlet Ball Valve.

10. The system is now ready for use.

11.

For new piping installations: After making the

connection to the System Outlet:

a. Open the faucet or tap closest to the filter system

b. Slowly open the Inlet Valve.

c. Allow the pipe to flush until all debris is removed.

Advertising