INSTALLATION (continued)

Rinse Valve Connection

1. Obtain a length of 3/4” garden hose long enough to

reach from the Rinse Valve to the drain.

2. Install a gasket in the end of the hose (non-drain end).

3. Connect the hose to the Rinse Valve fitting. Use a back-

up wrench on the fitting if required (Figure 5).

4. Direct the other end of the hose to the drain. Secure as

necessary.

NOTE: The drain MUST accommodate a flow of up to

5 gpm.

System Inlet Connection

The System Inlet has a 3/4” NPT male thread at the Inlet

Valve (Figure 6). Do NOT overtighten fittings as this could

cause the plastic ball valve to crack.

Use plastic fittings and a pipe thread sealant approved for use

on PVC fittings when making connections.

CAUTION

Do NOT use the Rinse Valve for consumable water.

Inlet Water Plumbing

The "T" Fitting with plug (supplied) should be installed at the

System Inlet. This fitting will be used for sanitizing the system

and downstream plumbing (Figure 6a).
Before connecting the fitting to the System Inlet, the plumb-

ing to the system must be flushed clear of all debris. Hold a

bucket at the inlet water line and slowly open the Inlet Water

Valve. Allow the pipe to flush until all debris is removed.

Filtered Water Permeate Outlet Connection

The System Outlet has a 3/4” NPT female thread at the Outlet

Valve (Figure 6). Do NOT overtighten fittings as this could

cause the plastic ball valve to crack.

Use plastic fittings and a pipe thread sealant approved for use

on PVC fittings when making connections.

3/4”

Garden

Hose

Connection

3/4”

Garden Hose

(not supplied)

directed

to drain

Rinse Valve Connection

Figure 5. Rinse Valve Connection

Figure 6. Inlet and Outlet Connections

Figure 6a. Installing the T-Fitting