Vzn series, Installation (continued) – A.J. Antunes & Co VZN-441HC 9700772 User Manual

Page 14

Advertising
background image

VZN SERIES

14

P/N 1011114 Rev. H 12/13

Installing and Rinsing the Carbon Element

The Carbon Element MUST be rinsed before using the

system the first time.

1. Install the new Carbon Element into the Carbon

Element Housing.

2. Screw the Carbon Element Housing (containing the

Carbon Element) into place on the Carbon Element

Head. The housing will come to a hard stop at the end

of the thread. Use a Filter Wrench if necessary.

NOTE: Do NOT overtighten the Carbon Element Housing.

3. Direct water from the Rinse Ball Valve to a drain.

4. Open the Rinse Ball Valve and close the Outlet Ball

Valve.

5. Turn on the water to the system by slowly opening the

Inlet Ball Valve.

6. Allow water to flow through the Carbon Element and

Carbon Element Housing to flush out trapped air and

any debris that may be present.

7. To help remove trapped air from the Carbon Element

Housing, press the RED Pressure Relief Button on the

top of the housing until water just begins to come out.

8. Rinse the Carbon Element for at least 5 minutes.

NOTE: Do NOT consume water used during this process.

9. When the rinsing is complete, close the Rinse Ball

Valve and open the Outlet Ball Valve.

10. The system is now ready for use.

INSTALLATION (continued)

Flushing the Outlet Plumbing

To ensure that the highest quality water is produced from the

system, the plumbing leading from the filter system must be

flushed clear of all debris after the system is hooked up. After

making the connection to the outlet of the filter system, open

the faucet or tap closest to the filter system, then slowly open

the Inlet Water Valve. Allow the pipe to flush until all debris is

removed.

Sanitizing the System and Lines

The plumbing must be sanitized to eliminate possible contam-

ination that may have occurred during the installation process.
One ounce (30 ml) of liquid chlorine bleach (regular bleach,

unscented 5.25 % - 6 % sodium hypochlorite) or Kay-5

sanitizer solution (Sodium Dichloro-s-Triazinetrione Dihydrate,

6%) or equivalent can be used to sanitize the plumbing.
The Kay-5 sanitizer solution is made by dissolving a 1 oz.

packet of Kay-5 powder in 2 oz. (60 ml) of clean warm water.

This can be done by removing 1 inch from the top of the

Kay-5 packet and adding the 2 oz. of warm water to the pack-

et. Mix with a coffee stirrer to dissolve. When added to the

system, this will create a 60-100 ppm chlorine solution.
NOTE: Follow the handling and safety instructions

supplied with the sanitizer.
NOTE: If installed, remove the Carbon Element and TAC

Cartridge from the system BEFORE Sanitizing.

1. Follow the steps in the

Rinsing the Ultra Filter

Cartridge in the Installation section of this manual.

2. Turn off the water to the system.

3. Open the faucet or tap closest downstream to the

system.

4. Allow the system and plumbing to drain.

5. Remove the plug installed in the sanitizing "T" fitting at

the inlet of the system. Allow the water to drain out of

the system.

6. Pour the sanitizer into the inlet sanitation fitting using a

cup or funnel. Be careful not to spill the sanitizer onto

clothing or skin.

7. Reattach the plug on the sanitation fitting.

8. Slowly turn on the water supply to the system.

9. Allow water to flow through the system and out of the

open faucet or tap until the smell of sanitizer is present.

10. Close the faucet or tap.

11. Let the system stand without water flow for at least 15

minutes to allow the sanitizer to sanitize the pipes.

12. After 15 minutes without water flow, open the faucet or

tap.

13. Allow water to flow through the system until the

presence of sanitizer is gone.

14. Open all other faucets and taps in line with the system

to flush any remaining sanitizer from the plumbing.

15. Close all faucets and taps.

Advertising
This manual is related to the following products: