VZN T5 SERIES

7

P/N 1011115 Rev. H 12/13

PERFORMANCE DATA SHEET

System has been tested according to NSF/ANSI Standard 42

and 53 for reduction of the substances listed below. The con-

centration of the indicated substances in water entering the

system was reduced to a concentration less than or equal to

the permissible limit for water leaving the system, as specified

in NSF/ANSI 42 or 53. While testing was performed under

standard laboratory conditions, actual performance may vary.

Performance Claims for Percent Reduction

Substance

Influent

Challenge

Concentration

Reduction

Requirement

Minimum

%

Reduction

cyst

1

minimum

50,000/L

99.95%

99.95%

Turbidity

11 ± 1 NTU

≤ 0.5 NTU

99.1%

Particulate Class I

Particles 0.5 to <

1µm

at least 10,000

particles /mL

≥ 85%

N/A

1based on the use of microspheres or Cryptosporium parvum oocysts

NOTE: The NSF/WQA information provided applies to the

Ultra Filter cartridge.

Do not use with water that is microbiologically unsafe or

of unknown quality without adequate disinfection before

or after the system. Systems certified for cyst reduction

may be used on disinfected waters that may contain fil-

terable cysts.

Filter Cartridge Capacities

Maximum Operating Pressure

100 psig (690 kPa)

Maximum Operating Temperature

100°F (38°C)

Minimum Operating Temperature

40°F (4°C)

Maximum Trans Membrane Pressure

45 PSI (3.1 Bar)

pH Range

3-10

MWCO

100 kD

NSF/WQA Certified Rated Service

Flow:
VZN-421HC-T5

7.9 gpm (30 l/m)

VZN-441HC-T5

13 gpm (49 l/m)

System Tested and Certified by NSF

International and WQA against NSF/ANSI

Standard 42 and 53 for the reduction of:

Standard No. 42: Aesthetic Effects

Nominal Particulate Reduction Class I

Standard No. 53: Health Effects

Cyst Reduction & Turbidity Reduction

as verified and substantiated by test data.

System Tested and Certified by WQA

against NSF/ANSI Standard 372

for lead-free compliance