flUsHInG anD startInG tHe sYstem

To ensure that the highest quality water is produced

from the system, the plumbing leading from the filter

system must be flushed clear of all debris after the sys-

tem is hooked up. After making the connection to the

outlet of the filter system, open a faucet or tap closest

to the filter system, then slowly open the inlet water

valve. Allow the pipe to flush until all debris is removed.

The unit also must be flushed to remove air and the

shipping/storage solution. For maximum quality, the

permeate water produced during the flushing procedure

must be discarded. Direct this permeate water to drain.

nOte: Ultra filter cartridge must be rinsed to drain

before use. rinsing to drain removes storage solution

and air. Do nOt rinse into carbon if present. carbon

life and/or performance may be affected.

1. Plug the power cord into the appropriate electri-

cal outlet. The display will power on and the LED

display will display the following for about two sec-

onds each:

8.8

F8 followed by its time settings in seconds

Fi and its time setting in minutes or hours.

The

F8 and Fi sequence repeats for 30 seconds

after which the unit automatically returns to the

Flush Interval Mode (Fi). The time setting for Fi will

be displayed and the decimal point will flash in one

second intervals.

2. Open the tap or faucet closest downstream to the

filter system.

3. Slowly open the inlet water valve and allow water

to enter the system.

InstallatIOn (continued)

4. Press and hold the

start button. After 6-7 sec-

onds, the drain valve will open and FL will appear

on the display.

5. Continue holding the

start button down for at

least 30 seconds to keep the drain open. This

flushes air out of the center of the hollow fibers.

The drain will remain open as long as the Start

button is pressed. Check to make sure that the

drain water is directed into the drain without

splashing.

6. Release the

start button. This closes the drain

valve. Water should continue to flow through the

system and out of the open tap. Allow water to

flow out of the tap for at least 15 minutes at maxi-

mum flow rate.

7. Close the tap and let the system stand with no

water flow for 15 minutes to allow any trapped air

to come out of the hollow fibers. Check for leaks

at all fittings.

8. After 15 minutes without water flow, open the

tap for 5 minutes to allow any trapped air to be

flushed out.

9. Close the tap. Flushing is complete.