maIntenance

system sanitization

The system and downstream plumbing should be sani-

tized at least once a year. When necessary, follow the

procedure in

sanitizing the system and lines in the

Installation section of this manual.

replacing the ultra filter cartridge

1. Open the faucet or tap closest downstream to the

filtration system.

2. Close the Inlet Water Valve and allow the system

to depressurize.

3. Place a bucket under the strainer at the inlet

connection to the system. Open the strainer by

unscrewing the cap. Water will flow out of the

strainer as the system drains.

4. Press the

flusH button to help drain the system.

5. Reattach the cap on the strainer when the water

flow stops. Unplug the power cord.

6. Using a strap wrench (up to 6” capacity), loosen

the top and bottom end Caps. Do NOT remove

the top and bottom End Caps yet.

7. Disconnect the Permeate Port Connection.

8. Using a screwdriver, remove the screws from the

Cartridge Bracket and set the bracket and screws

aside.

9. Unscrew the End Caps from the cartridge.

10. Install a new cartridge to the system using the

cartridge bracket and screws from Step 8.

11. Connect the Permeate Port Connection.

12. Inspect the O-rings to ensure they are clean and

not splitting or cut. For all O-rings, ensure they are

lubricated with an approved food grade lubricant

acceptable for drinking water use.

13. Screw each End Cap onto the cartridge. Tighten

with a strap wrench if necessary.

14. Plug in the power cord.

15. Open the Inlet Water Valve and allow the system

to pressurize.

16. Rinse the new Ultra Filter Cartridge before

placing the system back into operation. Follow

the

rinsing the Ultra Filter Cartridge and

sanitizing the system and lines procedures in

the Installation section of this manual to complete

the cartridge change.

17. When rinsing is complete, repressurize the

system.

figure 4. replacing the ultra filter cartridge

cartridge

bracket

cartridge

end cap

permeate

port

connection

Advertising