Ufc series water filtration system, Operation (continued), A.j. antunes & co – A.J. Antunes & Co UFC-216 9700603 User Manual

Page 11

Advertising
background image

UFC SERIES watER FIltRatIon SyStEm

11

P/N 1010907 Rev. A 03/12

A.J. Antunes & Co.

OperatIOn (continued)

programming timer

nOte: Once the Ufc unit is powered up, the

leD display cycles through the default or current

settings: flush Duration (fd) and its setting will

be followed by flush Interval (fi) and its settings.

at any time during this sequence, which lasts

approximately 30 seconds the UFC unit can be pro-

grammed.

setting the flush Interval (fi)

1. When Fi (Figure 5) is displayed, press and

release start button to view current setting .

2. To make a change, press and hold down start

button to scroll through settings - release button

at desired setting (Figure 6).

3. After ten seconds, unless start button is

depressed, unit automatically returns to

Flush Interval Mode.

nOte: fi times are displayed in ten minute inter-

vals, after fifty minutes they are displayed in hours

(table a).

figure 7. leD Display for flush Duration mode

figure 8. time setting fd mode (55 seconds)

table a. leD Display settings

figure 6. time setting fi mode (22 Hours)

figure 5. leD Display for flush Interval mode

setting flush Duration (fd)

2. When Fd is displayed, press and release start but-

ton to view current setting (Figure 7).

3. To make a change, press and hold down start

button to scroll through settings - release button

at desired setting (Figure 8).

4. After ten seconds, unless button is depressed,

unit automatically returns to Flush Interval Mode.

nOte:

fd

times are displayed in 5 second intervals

up to 60 seconds (table a).

1-

10 minutes

5

5 seconds

5- 50 Minutes

10

10 seconds

01 1 Hour

15

15 Seconds

12

12 Hours

30

30 Seconds

24 24 hours

60

60 Seconds

fi - flush Interval mode

fd - flush Duration mode

Advertising
This manual is related to the following products: