Operation, A.j. antunes & co – A.J. Antunes & Co UFC-440 9700616 User Manual

Page 10

Advertising
background image

UFC-420/440 water Filtration system

10

P/N 1010908 Rev. A 03/12

A.J. Antunes & Co.

OperatIOn

filtration process

Water filtration in the UFC Series is accomplished

using two modes: Flush Interval Mode, shown as Fi on

the LED Display and Flush Duration Mode (Fd on LED

display). During the Flush Interval, water enters the

inlet and flows through the filter element before exiting

the Permeate outlet as usable product water.

After a certain period of time, depending upon water

quality, the filter has to be cleaned. This is accom-

plished through the Flush Duration Mode. During

this mode, the drain valve opens and flushes the

membrane to remove debris collected inside the

membrane walls.

nOte: both the flush Interval mode and the flush

Duration mode can be automated by programming

the timer. During the flush Interval mode, the valve

is not powered in order to keep water filtering during

a power outage.

figure 4. leD Display, front panel

leD Display

Fi - Flush Interval Mode is the time between flushings

and is displayed in minutes or hours.

Fd - Flush Duration Mode is the amount of time used

to flush and remove debris from filter cartridge and

is displayed in seconds.

FL - Manual Flush Mode operation, solenoid is

manually activated by the user.

starting the system

Power up the unit.

The LED read-out displays the following for about two

seconds each:

1. 8.8

2. Fd followed by its time settings in seconds.

3. Fi and its time setting, in minutes or hours.

The

Fd, Fi sequence repeats for 30 seconds

after which, the unit automatically returns to the

Flush Interval Mode (Fi). The time setting for Fi

will be displayed and the decimal point will flash in

one second intervals.

nOte: the timer can be programmed immediately

after start-up or while in flush Interval mode.

figure 3. proper Draining

2”

minimum

2”

minimum

floor

Drain

secure

end

Drain line

from system

Drain line

from system

secure

end

Drain

standpipe

Advertising