Standard networked controller – HID EDGE EVO EH400-K Standard Controller Installation Guide User Manual
Page 4

Standard Networked Controller
EH400-K
82000-921 C.0
INSTALLATION GUIDE
4
©2009 - 2011 HID Global Corporation. All rights reserved.
ports of the EH400-K. The I/O ports may be configured to provide the following output current capacity.
Device
Ports
Conditions
I out
EDGE EVO Hi-O Standard Network
Controller (EH400-K)
Strike / Aux
NC or NO
DC Output
+12VDC unregulated
(@ +12VDC EDM-M input)
600 mA*
+24VDC unregulated
(@ +24VDC EDM-M input)
600 mA*
+12VDC regulated
(@ +24VDC EDM-M input)
3 mA*
Dry Jumpers
+12VDC to +24VDC External
2.00 Amp**
Reader Power
+9.8VDC to +12.25 VDC
320-600mA*
* = Combined output ratings, not to exceed 1.2 Amp
** = Each relay
Ensure door peripherals connected to the Strike/AUX relays (regulated/unregulated) do not exceed 1.2 Amps combined.
Alternatively, the door peripherals may be connected to the Strike/AUX relays configured for Dry contact up to 2 Amps.
Ensure Wiegand / Clock-and-Data readers attached to the reader port do not exceed:
320mA @ +9.8VDC
or
600mA @ +12.25VDC