Specifications, Wiring, Internal optical tamper – HID EDGE EVO Hi-O Interface Door Module Installation Guide User Manual
Page 2: Relay jumpers, Door module

Door Module
EDM-M
82342-901 B.1
INSTALLATION GUIDE
2
©2009 - 2011 HID Global Corporation. All rights reserved.
Wiring
10
P3
1
4
P1 1
Hi-O Group Select Jumper
Short = Group 1, Open = Group 2
Outside Door
Inside Door
( )
CAN V+
GND
CAN H
CAN L
Relay Jumpers
6
P10
1
P9
P5
P8
P6
P4
P7
HI-O CANbus
Door
Mon
REX
*
-
+
BATT
AC
-
+
-
+
-
+
DS
NC
CO
M
NO
AUX
SENSE
* Internal Optical Tamper Disable Jumper
NC
CO
M
NO
Note: Connect the Door Monitor to avoid a Force Door Alarm.
Internal Optical Tamper
To disable the internal optical tamper sensor for the right side PCB (reader interface board), attach a jumper wire from P3 pin 1
to P3 pin 2.
Note: If desiring an external tamper, wire an unsupervised Normally Closed contact and replace the jumper.
Relay Jumpers
AUX Wet
CAN V+
AUX Wet
+12VDC
AUX Dry
DS Wet
CAN V+
DS Wet
+12VDC
DS Dry
3
1
P9
P5
P8
3
1
3
1
3
1
P6
P4
P7
3
1
3
1
JUMPER =
Optional
Supervised Inputs
1-6K
N/O
1-6K
N/C
1-6K
1-6K
N/O