1 Parts

List

PARTS LIST (Included)

Quantity

- HID MIFARE Reader with snap-on
cover and 18in.

1

- #6-32 x 1” self-tapping panhead
screw

2

- Installation manual

1

PARTS LIST (Not-Included)

Quantity

- Wire splice

9

- DC Power supply 12 VDC

1

2 Mounting

Instructions

• Determine an appropriate mounting location. The

reader may be mounted to any surface, including
metal.

Drill two (2) 3/32-inch (2.5mm) holes

approximately 1 inch deep for mounting the
reader.

• Drill a 5/8-inch (16mm) hole for the cable.
• A single-gang (2S) electrical junction box may

also be used; reader fits US hole pattern, and the
6-32 screws work with the J-box.

• Remove the snap-on cover from the reader and

secure the reader to the mounting surface.

• Route the cable from the reader and/or power

supply to the host. A linear type power supply is
recommended. Check all electrical codes for
proper cable installation.

• For the cable connection to the panel - use Alpha

#1299C or equivalent.

• Test the operation of the reader (Section 4). After

completion of the test, replace the snap-on cover.

• See Figure 1 for product and mounting

dimensions.

• For proper regulatory compliance, the drain wire

should be disconnected at the power supply end
of the cable.

• Changes or modifications not expressly approved

by the party responsible for compliance could
void the user’s authority to operate the
equipment.

• The Reader is intended to be powered from a

limited power source output of a previously
certified power supply.

3 Connecting the Reader

• Connect the reader to the host according to the

wiring table below and the host installation guide.

Signal

Color

DB9F

DB25F

9-14 VDC

Red

-

-

GND

Black

Pin 5

Pin 7

D0

Green

-

-

D1

White

-

-

GRN LED

Orange

-

-

RED LED

Brown

-

-

Beeper
HOLD
Not Used
RX
DTR
TX
SHLD GND

Yellow
Blue
Violet
Pink
Gray
Tan
Drain

-
Pin 1
-
Pin 2
Pin 4
Pin 3
-

-
Pin 8
-
Pin 3
Pin 20
Pin 2
-


4 Testing and Operation

• When power is applied to the reader the beeper

will beep and flash the LED green three times.

• Present an ID card to the reader. The LED will

momentarily turn green while the beeper beeps
once, indicating that the card was read
successfully.

• Please note that typical read range for MIFARE

cards is .75 to 1.5” (20 – 37 mm).



Important Product Specifications

Power supply
Absolute Maximum Voltage
Maximum Current at 12V
Operating Voltage Range

Linear type
16 VDC
50mA
9.0 – 14.0 VDC

Maximum cable distance
To host

50 ft RS-232
500 ft Wiegand

Operating temperature range -30 to 65

°C


FCC Compliance Statement:
This device complies
with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired operation.

5 Card

Compatibility

Advertising