4 door module groups 1 & 2, 5 door interface board groups 1 & 2, Standard networked controller – HID EDGE EVO Solo ESH400-K Networked Controller Installation Guide User Manual
Page 7: 4 tamper (reader interface board), 5 door interface board groups 1 and 2

82000-921, D.1
INSTALLATION GUIDE
7
©2009 - 2012 HID Global Corporation. All rights reserved.
Standard Networked Controller
EH400-K
3.4 Tamper (Reader Interface Board)
The Reader Tamper + and - are implemented allowing a connection for an open collector external tamper from a
reader, such as iCLASS.
Note: Connect P2, Pin 2 (GND) from the Reader Interface Board to the same ground as the reader power, if the reader
is not powered by the units 12 VDC output port.
3.5 Door Interface Board Groups 1 and 2
3.5.1 Group 1
Following are the inputs when the unit is configured for Group 1.
Input
Port
Pin
AC -
P3
Pin3
AC +
P3
Pin 4
BATT -
P3
Pin 5
BATT +
P3
Pin 6
REX -
P3
Pin 7
REX +
P3
Pin 8
Door Mon -
P3
Pin 9
Door Mon +
P3
Pin 10
3.5.2 Group 2
Following are the inputs when the unit is configured for Group 2.
Input
Port
Pin
Input 4 -
P3
Pin3
Input 4 +
P3
Pin 4
Input 3 -
P3
Pin 5
Input 3 +
P3
Pin 6
Input 2 -
P3
Pin 7
Input 2 +
P3
Pin 8
Input 1 -
P3
Pin 9
Input 1 +
P3