3.3

Procedure 3 (optional): Create An Out-of-Band Delivery Gateway

ActivIdentity 4TRESS AAA supports OOB authentication (SMS) via phones. The actual SMS one-time password
is a random number generated by the Appliance and sent to the end user through a delivery gateway. To create a
gateway, perform the following steps using the AAA Server Administration Console.

1. Select Tools, and then click Options.

2. Select the SMS Gateway tab.

3. Select the Protocol to use for sending the SMS to the cell phone.

4. For SMS Center Address

, enter the IP address or domain name of the SMS Center’s server.

5. Enter the SMS Center Port number for the above server.

6. Enter the login and password credentials that the AAA Server uses to authenticate to the SMS Center server.

7. For Cell Phone Number LDAP Attribute

, enter the attribute used by your organization’s LDAP directory for

user phone numbers.

8. Customize the text of the message you want sent to users (for ex

ample, “Here’s your one time password:”)

and then click OK.