Karcher IVL 50-24-2 User Manual

Page 13

Advertising
background image

– 4

Note
Water based cooling lubricants can cause
a bacterial contamination. These sedi-
ments can plug up the openings and gaps
in the filter basket. Wear appropriate pro-
tective gear during the removal.

Empty the container and filter basket.

Remove the sediments from the con-
tainer and the filter basket.

Dispose of the sediments, container
and filter basket contents according to
the applicable rules and regulations.

Empty the liquid container.

Empty the filter basket for solids.

Switch off the appliance using the On/
Off switch.

Dismantle the accessory and rinse it
with water and let dry if necessary.

Note
Empty the vacuum cleanter after each use
and let it dry with the container open.

Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.

When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.

Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.

Rinse the appliance and the accesso-
ries with fresh water at regular intervals
and let them dry.

In order to avoid bacteria, do not leave
the chips and liquids inside the appli-
ance.

During extended operation breaks,
open the cover to let the residual mois-
ture escape.

Clean the container

Shutting down

Transport

Storage

Maintenance and care