Troubleshooting, Warranty – Karcher IVC 60-24-2 Tact User Manual

Page 15

Advertising
background image

– 4

Open filter door.

Replace the flat pleated filter.

Close the filter door, it must lock into
place.

Pull the locks of the placement mechan-
ics up.

Pull the push handle upward. The con-
tainer is unlocked and lowered.

Pull the container out by the handle.

Clean the thermal probe and the protec-
tive cover with a moist cloth.

Replace the battery and lock it with the
sliding bow.

ƽ

Danger

First pull out the plug from the mains before
carrying out any tasks on the machine.

Check the receptacle and the fuse of
the power supply.

Check the power cable, the power plug
and the thermal probe of the device.

Turn on the appliance.

Empty the container.

Check whether the protective cover is
available and the side opening of the
protective cover points to the right
placement mechanics (see illustration
of appliance).

Clean the thermal probe and the protec-
tive cover with a moist cloth.

Turn the appliance off and back on.

Clean the thermal probe and the protec-
tive cover with a moist cloth.

Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.

Check the suction head and the recep-
tacle for proper seating.

Ensure the filter cover properly locks
into place.

Replace the flat pleated filter.

Check for proper installation of the flat
pleated filter.

Replace the flat pleated filter.

Clean the thermal probe and the protec-
tive cover with a moist cloth.

Suction hose is not connected.

Suction hose used is too short (< 3m) or
the diameter is too large.

Inform Customer Service

Inform Customer Service

The warranty terms published by the rele-
vant sales company are applicable in each
country. We will repair potential failures of
your appliance within the warranty period
free of charge, provided that such failure is
caused by faulty material or defects in man-
ufacturing. In the event of a warranty claim
please contact your dealer or the nearest
authorized Customer Service centre.
Please submit the proof of purchase.

Exchanging the flat pleated filter

Clean the thermal probe

Troubleshooting

Suction turbine does not run

Suction turbine turns off

Suction turbine does not start again

after the container has been

emptied

Suction capacity decreases

Dust comes out while vacuuming

Automatic shut-off (wet vacuum

cleaning) does not react

Automatic filter cleaning is not

working

Automatic filter cleaning cannot be

switched off

Warranty

15

EN

Advertising