Troubleshooting, As and when required, Unit does not work – Karcher HD 4-5-32-4 S Eb User Manual

Page 12: Unit does not come up to pres- sure

Advertising
background image

Operating Instructions

English

12

As and when required

„ Emptying and cleaning the detergent

tank

– Pull out the screw cap and hose for the

detergent tank.

– Place the unit on its rear.

– Empty and clean the detergent tank.

Troubleshooting

Danger!
Before any repair work is undertak-

en, switch the unit off and pull out the power
plug. Have electrical components checked
and repaired only by authorised Customer
Service personnel.
For faults which are not identified in this
chapter, or when in doubt or when express-
ly instructed to do so, consult authorised
Customer Service personnel.

Indicator light

The indicator light shows the operating sta-
tus (green) and faults (red).

To reset:
„ Switch off the unit switch.
„ Wait a moment.
„ Switch the unit back on again.

Operating status display
„ Constant green light:

– Unit is operational.

„ 1 x flashing green:

– Operational readiness expired after

30 minutes.

– The unit switched off after 30 minutes of

permanent operation (safety feature in
the case of a burst high-pressure hose).

Fault display
„ 1 x flashing red:

– High-pressure side leaking. Check high-

pressure hose, hose connections and
hand-held spray gun for leaks.

„ 2 x flashing red:

– Motor too hot. Switch off the unit switch.

Leave unit to cool down. Switch the unit
back on again.

„ 3 x flashing red:

– Fault in the power supply. Check the

mains connection. Check supply fuses.

„ 4 x flashing red:

– Current consumption too high. Consult

Customer Service

Unit does not work

„ Availability time has run out. The indica-

tor light will flash green. Switch the unit
off and then on again.

„ Check connecting cable for damage.
„ Consult Customer Service if there is an

electrical fault.

Unit does not come up to pres-
sure

„ Set nozzle to "high pressure".
„ Clean/replace nozzle.
„ Clean the fine filter, replace if required.
„ Evacuate air from the cleaner (see

Switching on the unit).

„ Check water inlet volume (see Technical

Specifications).

„ Check all supply lines to the pump for

leaks or obstructions.

„ Seek the help of Customer Service if

necessary.

!