Factory default switch – ADTRAN NetVanta 300 Series User Manual
Page 27

NetVanta 300 Series Hardware Installation Guide
Unit Installation
61200422L1-34D
Copyright © 2006 ADTRAN, Inc.
27
Factory Default Switch
•
If the factory default switch is pressed during bootup, the unit will stay in bootstrap mode. Since the unit
has no serial port, Telnet has been built into the boot code. The default IP address is 10.10.10.1.
•
If the factory default switch is pressed and held for 5 seconds after boot, the
ETHERNET
interface on
the NetVanta 340 (or the
VLAN 1
interface on the NetVanta 344 and NetVanta 347) will default to
10.10.10.1 and all access policies will be removed from that interface.
•
If the factory default switch is pressed for 30 seconds, a default configuration will overwrite your
existing configuration and reboot the unit.
The default switch must be pressed WHILE the power light is flashing green. Do not press
the default switch BEFORE the power light is flashing green, as this will cause boot to be
missed.