2. Technical Gas Data

a. Gas Specifications

b. Gas Connections

Inlet connection ------------ 1/2" inch N.P.T.

Inlet supply size ------------ 1/2" inch N.P.T. (minimum)

Btu/hr input (per dryer) --- 130,000 (32,760 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure must

be consistent between a minimum of 6.0 inches and a maximum of 12.0 inches water column (W.C.)

pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve's internal pressure regulator blocked open so

that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas

valve pressure tap must be a consistent 10.5 inches water column (W.C.). There is no regulator or

regulation provided in an L.P. dryer. The water column (W.C.) pressure must be regulated at the

source (L.P. tank) or an external regulator must be added to each dryer.

* Drill Material Size (D.M.S.) equivalents are as follows:

Natural Gas ..................... #25 = 0.1495” (3.7973 mm)

Liquid Propane Gas ........ #43 = 0.0890” (2.2606 mm)

T

YP E OF

G

AS

Liquid Propane

(L.P.)

Conversion Kit

Part Number

MODEL

NUMBER

BTU

Per Hour

Rating

kcal/hr

Rating

Natural

Liquid Propane (L.P.)

Qty. D.M.S.*

Part

Number

Qty. D.M.S.*

Part

Number

MDG-50

130,000

32,760

2

#25

140853

2

#43

140809

874044

T

YPE OF

G

AS

Natural

Liquid Propane (L.P.)

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

Inline Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

10.5 inches W.C.

26.1 mb

Shaded areas are stated in metric equivalents

* Measured at outlet side of gas valve pressure tap when gas valve is on.