Important, Manual reset hi-limit instructions – American Dryer Corp. AD-115ES User Manual

Page 65

Advertising
background image

61

SECTION IX

BURNER and LINT (TUMBLER) CHAMBER

MANUAL RESET HI-LIMIT INSTRUCTIONS

I M P O R T A N T

MANUAL RESET HI-LIMIT INSTRUCTIONS

FOR TIMER OR PHASE 5 WITHOUT HEAT FAULT

(GAS MODELS ONLY)

This dryer was manufactured with a burner and tumbler/lint chamber manual reset burner hi-limit thermostat.

If either manual reset burner hi-limit thermostat is open prior to the start of the drying cycle, or during the cycle,

the dryer will not recognize the open state of the burner hi-limit thermostat and will start or continue through the

drying cycle with no heat. The applicable manual reset hi-limit thermostat must be reset manually.

This hi-temperature condition may be caused due to a restricted exhaust, poor airflow or improper burner

oven operation.

The location of the burner manual reset hi-limit switch is on the right side of the burner box.

IMPORTANT

This dryer is equipped with a burner

hi-limit and tumbler/lint chamber hi-limit

thermostat which must be reset manually.

WARNING: Discontinue power to dryer

before attempting to reset hi-limit.

ADC P/N: 114093

Advertising