Sony VPL-VW70 User Manual

Page 12

Advertising
background image

8

VPL-VW70

<Table 1>

<Table 2>

Remarks

Item Number

Data

Item

Upper byte

Lower byte

Data

Upper byte

Lower byte

USER BIAS RED

00h

53h

FFE2h to 001Eh (

_30 to 30)

Set/Get

USER BIAS GREEN

00h

54h

FFE2h to 001Eh (

_30 to 30)

USER BIAS BLUE

00h

55h

FFE2h to 001Eh (

_30 to 30)

Iris Sensitivity

00h

56h

Recommend

00h

Fast

01h

Slow

02h

Iris Manual

00h

57h

00h to 64h (0 to 100)

xvColor

00h

5Ah

Off

00h

On

01h

Status Error

01h

01h

NO ERROR

00h

Get only

LAMP ERROR

01h

FAN ERROR

02h

COVER ERROR

04h

TEMP ERROR

08h

D5V ERROR

10h

POWER ERROR

20h

NVM Data ERROR

80h

25h

LENS SHUTTER

01h

ERROR

Status Power

01h

02h

STANBY

00h

START UP

01h

STARTUP LAMP

02h

POWER ON

03h

COOLING1

04h

COOLING2

05h

SAVING COOLING1

06h

SAVING COOLING2

07h

SAVING STABY

08h

Lamp Timer

01h

13h

USE TIME

0000h-FFFFh

*1

Sircs (15bit category)

17h

Refer to Table4

-----

00h

00h

Set only

*2

Sircs (20bit category)

19h

Refer to Table5

-----

00h

00h

1Bh

Refer to Table6

-----

00h

00h

*1 Example) In case the lamp timer indicates 1000H, return values are [03h] upper byte and [E8h] lower byte.
*2 It is corresponded to single command only.