Varies; sends 4 data bytes for each recipe step, Byte 1 = number of recipe steps, Byte 2 = recipe status – Apex Digital 5708009-C User Manual

Page 100: Byte 3 = recipe mode (1 = time, 2 = joule), 4 data bytes 32-bit value, Requests the duty cycle in% on time, 2 data bytes 16-bit value, 3 data bytes 3 ascii characters

Advertising
background image

4-54

5708009-C

Advanced Energy

®

188

report

recipe step

setpoints/

run times

Reports the setpoints and run times for each
recipe step. The number of data bytes
returned depends on the number of steps in
the recipe. For each recipe step, 4 data bytes
returned, indicating:

First 2 bytes = recipe step setpoint in
watts

Second 2 bytes = recipe step run time in
hundredths of seconds or joules,
depending on the recipe mode (recipe
mode is reported by CMD 188)

Varies; sends

4 data bytes

for each

recipe step

189

report
recipe
steps,

status, and

mode

Reports the number of steps in the recipe, the
status of the most recent recipe run, and the
recipe mode (time or joules). Returns 3 data
bytes:

• Byte 1 = number of recipe steps
• Byte 2 = recipe status:

bit 0 indicates ignition (1 = ignition

detected; 0 = ignition not detected)

bits 1, 2, and 3 indicate the most

recently completed step number

bits 4–7 are reserved or unassigned

• Byte 3 = recipe mode (1 = time, 2 =

joule)

193

read

pulsing

frequency

Requests the RF pulsing frequency in Hz (set
with CMD 93).

Note: The response contains 4 data bytes. All

represent frequency (LSB first).

4 data bytes
32-bit value

196

read

pulsing

duty cycle

Requests the duty cycle in% ON time

Note: The response contains 2 data bytes

which represent duty cycle (LSB first)
in percent on time.

2 data bytes
16-bit value

198

read

mainframe

software

revision

level

Requests the revision level of the mainframe
software. The returning packet contains three
ASCII characters—one letter, followed by a
two-digit number. Used in conjunction with
CMD 130 to obtain the version/revision of
the mainframe software.

3 data bytes

3 ASCII

characters

Table 4-6. Host Port Commands for RS-232 with AE Bus (Continued)

Command

Description

Number of

Host Data

Bytes

Number of

Response

Data Bytes

Advertising