CONNECTIONS

60HZ

0

C O N T R O L

Figure 2 1461 Rear Panel

CONNECTIONS

Video Input

Auxiliary Start Relay Connections

The

CONTROL connector is also used to access a

Connect a good grade of

video cable from the camera

normally open, SPST relay which can be used to activate a

to the VIDEO IN BNC Connector on the rear panel of the

VCR or other devices during an alert. The relay contacts

1461. The 1461 has a passive loop-thru input. It does not

provide a closure between pins 3 and 4 when an alert condition

terminate the input in 75 ohms. The video input cable should

occurs. CAUTION: DO NOT USE THIS RELAY TO

be terminated in 75 ohms at the end of the run.

SWITCH LINE VOLTAGES. The relay contact ratings are:

Video Output

Connect a good grade of

video cable from the VIDEO

BNC connector on the rear panel of the 1461 to the video

input of the monitor or video switcher. This cable should be

terminated in 75 ohms, or if looped thru the monitor or
switcher, terminated at the end of the run.

.

Automatic Switcher Call-Up Connections

Connections to an external switcher are made at the
CONTROL connector on the rear panel of the 1461. Pin 2
provides a logic-level closure during an alert for remote call-up

of a switcher. A typical system connection for switcher call-up
is shown in the Appendix. The CONTROL connector pin
definitions are:

PIN1

Ground

PIN2

Switcher Logic Out

PIN3

Auxiliary Relay Contact

PIN4

Auxiliary Relay Contact

PIN5

No Connection

Pin 1 is at the top of the connector, see Figure 2.

Power:

10 VA max.

Voltage:

30

or RMS max.

Current:

0.25 A DC or RMS max. (resistive load)

Power

The model number and rated power are shown on the rear
panel of each unit. No power On/Off switch is provided. The
LED on the front panel is lit when power is applied to the unit.

1461 120 VAC, 60 Hz nominal. Insert the pendant

3-wire cord and plug into a mating power source.

Model

13.5 V DC (11 to 18 VDC). Attach the

leads extending from the rear panel to the power source. A

separate chassis ground terminal is also provided.

Red Wire with Fuse Holder (+) (hot) lead.
Black Wire (ground) lead.

Model 1461X 230 VAC,

Hz nominal. Insert the

pendant 3-wire cord and plug into a mating power source.

A mating

plug is provided. Note that this plug also

provides connections for the auxiliary start relay.