5. mounting notes – DMC FST Series User Manual

Page 9

Advertising
background image

DER-S0096A

9

Rev. 5 ©2005 - 2013 DMC Co., Ltd.

FST Series Product Specifications

5-5. Mounting Notes

§ Gap between the Bezel and Touchscreen

A gap of approximately 0.5mm is needed between the bezel
and the top electrode. It may cause unexpected input if the
gap is too narrow.

§ Cushion

If a cushion is used between the bezel and the top electrode,
the cushion must be free enough to absorb the expansion and
contraction difference between the bezel and the top
electrode. If the cushion is squashed too hard, the expansion
and the contraction difference may cause the distortion to the
top electrode.
The cushion must be positioned within the insulation area.

§ Tolerance

There is a tolerance of 0.2 to 0.3mm for the dimensions of the
touchscreen and the tail. A gap must be made to absorb the
tolerance in the case and the connector.

§ Tail

The tail must not be forcibly stressed or bent too hard to avoid
the conduction in the insulated area and wire breaking.

§ Mounting

Touchscreen must be held from the bottom such as the
structure gluing the touchscreen onto the display. If the
touchscreen is glued to the bezel, the adhesion between the
top and bottom electrode is stressed and may come off.

§ Forbidden Area

The area within 2mm from the insulation area is structurally
week for the pressure, espcially for pen use. The film may be
forcibly bent and may cause defection. This area must be
protected by the bezel and input must be avoided.

§ Air Vent

Most of the touchscreens have the air vent to equalize the
inside air pressure to the outside one. The air vent must be
open and liquid contact must be avoided as the liquid may be
absorbed if the lquid is accumilated near the air vent. The top
electlode must not be swelled by the air pressure from inside
of the case.

0

.5

m

m

Top Electrode

Bezel

Bezel

Display

Forbidden Area

Bezel

Tail

0.2 - 0.3mm

Case

Top Electrode

Bezel

Cushion

Insulation Area

Advertising