Self-diagnosis function – Sony SDM-S94 User Manual

Page 21

Advertising
background image

21

GB

Displaying this monitor’s information

While the monitor is receiving a video signal, press and
hold the MENU button for more than 5 seconds until the
information box appears.

Press the MENU button again to make the box disappear.

If any problem persists, call your authorized Sony dealer and give
the following information:
• Model name: SDM-S74 or SDM-S94
• Serial number
• Detailed description of the problem
• Date of purchase
• Name and specifications of your computer and graphics board
• Type of input signals (analog RGB/digital RGB)

Self-diagnosis function

This monitor is equipped with a self-diagnosis function. If there is
a problem with your monitor or computer(s), the screen will go
blank and the 1 (power) indicator will light up in green. If the
1 (power) indicator is lit in orange, the computer is in power
saving mode. Try pressing any key on the keyboard or moving the
mouse.

If the picture disappears from the screen and the

1

(power) indicator is green

1

Turn off the

1

(power) switch and disconnect the

video signal cables from the monitor.

2

Turn the monitor on by pressing the

1

(power)

switch.

If all four color bars appear (white, red, green, blue), the monitor
is working properly. Reconnect the video signal cables and check
the condition of your computer(s).
If the color bars do not appear, there is a potential monitor failure.
Inform your authorized Sony dealer of the monitor’s condition.

MENU

Example

Model name

Serial number

Week and year
of manufacture

INFORMATION

MODEL : SDM-S74
SER. NO : 1234567
MANUFACTURED : 2004-52

1

(power)

indicator

Advertising