Communication parameter, Pin configuration, Communication data format – Sony FWD-40LX1 User Manual

Page 5

Advertising
background image

1

FWD-40LX1

FWD-32LX1R

1. Communication Parameter

Communication system

RS-232C

Synchronous system

Asynchronous communication

Baud rate

9600 bps

Character length

8 bit

Parity

None

Start bit

1 bit

Stop bit

1 bit

Flow control

None

2. Pin Configuration

1

2

3

4

5

Display side (D-sub 9-pin)

_

External view

_

6

7

8

9

1

2

3

4

5

6

7

8

9

Host side (D-sub 9-pin)

_

External view

_

FWD-40LX1

FWD-32LX1R

Personal computer

Pin No.

Signal

1

NC

2

RD

3

TD

4

NC

5

GND

6

NC

7

NC

8

NC

9

NC

Pin No.

Signal

1

NC

2

RD

3

TD

4

NC

5

GND

6

NC

7

NC

8

NC

9

NC

3. Communication Data Format

(a) Control (Host

Request of Write to Display)

No.

Item

Value

1

Header

0x8C:Control

2

Category

0xXX

3

Function

0xXX

4

Data1 (Length)

0xXX

5

Data2 (Data1)

0xXX

:

:

0xXX

:

:

0xXX

X

Data (X-3)

0xXX

X

+

1

Check Sum

0xXX

*

Check Sum: Sum total of 1 to X. Lower one-byte data is validated when a

value exceeds 255 (1 byte).

*

Set the command interval to 500 ms or more when transmitting the
Control command continuously.

*

Set the command interval to 500 ms or more when transmitting the same
command (Enquiry) after the Control command.

(b) Enquiry (Host

Request of Read to Display)

No.

Item

Value

1

Header

0x83:Enquiry

2

Category

0xXX

3

Function

0xXX

4

Data1

0xFF

5

Data2

0xFF

6

Check Sum

0xXX

*

Check Sum: Sum total of 1 to 5. Lower one-byte data is validated when a

value exceeds 255 (1 byte).

Advertising