Cleaning instructions, Indoor unit, Front panel – Panasonic CUYE9QKE User Manual

Page 8: Air fi lters, Anti-bacterial fi lter

Advertising
background image

8

Cleaning instructions

To ensure optimal performance of the unit,

cleaning has to be carried out at regular intervals.

Dirty unit may cause malfunction and you may

see error code “H99”. Please consult authorised

dealer.
• Switch off the power supply and unplug before

cleaning.

• Do not touch the aluminium fi n, sharp parts may

cause injury.

• Do not use benzine, thinner or scouring powder.

• Use only soap ( pH 7) or neutral household

detergent.

• Do not use water hotter than 40 °C.

Indoor unit

Wipe the unit gently with a soft,

dry cloth.

Front panel

Wash gently and dry.

Remove the front panel

POWER

TIMER

Raise

1

Pull out

2

Close it securely

Press both ends of the front panel

3

POWER

TIMER

Insert at both sides

1

Close down

2

POWER

TIMER

Aluminium fi n

Front panel

Air fi lters

Indoor unit

Anti-bacterial fi lter

Air fi lters

Every 2 weeks

• Wash/rinse the fi lters gently

with water to avoid damage to

the fi lter surface.

• Dry the fi lters thoroughly under shade, away from

fi re or direct sunlight.

• Replace any damaged fi lters.
Remove air fi lter

Attach air fi lter

Insert into the unit

Anti-bacterial fi lter

(CS-RE9QKE CS-RE12QKE CS-RE15QKE

CS-UE9QKE CS-UE12QKE)

Anti-bacterial fi lter.

• Clean the fi lter whenever necessary.

• Wash/rinse the fi lter gently with water to avoid

damage to the fi lter.

• Dry the fi lter thoroughly under the shade, away

from fi re or direct sunlight.

• Replace the fi lter every 10 years or replace any

damaged fi lter. Part no.: CZ-SA22P

For seasonal inspection after extended non-use

• Checking of remote control batteries.

• No obstruction at air inlet and air outlet vents.

• Use Auto OFF/ON button to select COOL/HEAT

operation. After 15 minutes of operation, it is normal to

have the following temperature difference between air

inlet and air outlet vents:

COOL: ≥ 8 °C

HEAT: ≥ 14 °C

For extended non-use

• Activate HEAT mode for 2~3 hours to remove

moisture left in the internal parts thoroughly to prevent

mould growth.

• Turn off the power supply and unplug.

• Remove the remote control batteries.