Panasonic WHSXC12D6E51 User Manual

Page 5

Advertising
background image

ENGLISH

5

SETTING UP THE SPECIAL FUNCTIONS

SETTING UP THE SPECIAL FUNCTIONS

• After initial installation, you can manually adjust the settings. The initial setting remains active until the user changes it.

• The control panel can be used for multiple installations. Some functions may not be applicable to your unit.

• Ensure the operation LED is in OFF condition before setting.

SET

SELECT

CANCEL

SETTING

STATUS

CHECK

1. Press

SET

and

CHECK

simultaneously for 5 seconds to enter special setting mode.

“SETTING” and “STATUS” indicator is ON.

2. Press or

to browse functions.

3. Press

SELECT

to enter function.

4. Press or

to enable YES or disable NO function, or set other options.

5. Press

SET

to confi rm.

Set Control Panel’s Display Description

1

External Thermo Controller (YES / NO)

To set external thermo controller connection.

2

HEATER

Indoor Backup Heater Capacity Selection (3kW / 6kW / 9kW)

To reduce the heater power whenever unnecessary. Options vary depending on model.

3

Water System Freeze Prevention Function (YES / NO)

To activate or deactivate water system freeze prevention function when unit is OFF.

4

TANK

Tank Connection (YES / NO)

To set tank connection.

Note: If select “Tank connection” is “NO”, Set 5 ~ 14 are skipped.

5

SOLAR

Solar Priority (YES / NO)

To choose the solar use for water tank heat up.

6

COOL

Cooling Priority (YES / NO)

To choose the room cooling as priority during COOL + TANK mode.

If select “Cooling priority” is “YES”, Set 8 ~ 9 are irrelevant to COOL + TANK mode.

7

HEAT

Heating Priority (YES / NO)

To choose the room heating as priority during HEAT + TANK mode.

Note: If select “Heating priority” is “YES”, Set 8 ~ 9 are irrelevant to HEAT + TANK mode.

8

COOL/HEAT

Cooling/Heating operation Interval Set

To set timer for Cool mode or Heat mode during COOL + TANK mode or HEAT + TANK mode

(0.5hour ~ 10 hours). If both “Heating priority” and “Cooling priority” are “YES”, Set 8 ~9 are skipped.

9

TANK

Tank Heat-up Interval Set

To set timer for Tank during COOL + TANK mode or HEAT + TANK mode

(5minutes ~ 1hour 35minutes).

10

BOOSTER

Booster Heater Function (YES / NO)

To activate or deactivate tank booster heater function

Note: If select “Booster heater function” is “NO”, Set 11 is skipped.

11

BOOSTER

Booster Heater Delay Timer Set

To set delay timer for booster heater to ON if water tank temperature is not reached

(20minutes ~ 1hour 35minutes).

Do not use the system during sterilization to prevent scalding or overheat during shower.

The sterilization function fi eld settings must be confi gured by the authorized dealer according to local laws and regulation.

12

Sterilization (YES / NO)

To set sterilization, if required.

Note: If select “Sterilization” is “NO”, set 13 ~ 15 are skipped.

13

Sterilization Day & Time Set

To set timer for sterilization (only once a week, will operate even in standby condition).

14

Sterilization Temperature Set

To set temperature for sterilization function (40°C ~ 75°C).

15

Sterilization Continue Time

To set timer to maintain heating temperature in order to complete the sterilization

function (5minutes ~ 1hour).