Troubleshooting – Panasonic CSRE12HKE User Manual

Page 7

Advertising
background image



ENGLISH

NOTE :

Symptom

Check

Heating/Cooling operation is not working

efficiently.

• Set the temperature correctly.

• Close all doors and windows.

• Clean or replace the filters.

• Clear any obstruction at the air inlet and air outlet vents.

Noisy during operation.

• Check if the unit has been installed at an incline.

• Close the front panel properly.

Remote control does not work.

(Display is dim or transmission signal is weak.)

• Insert the batteries correctly.

• Replace weak batteries.

The unit does not work.

• Check if the circuit breaker is tripped.

• Check if timers have been set.

The unit does not receive the signal from the

remote control.

• Make sure the receiver not obstructed.

• Certain fluorescent lights may interfere with signal transmitter. Please

consult your nearest dealer.

Symptom

Cause

Mist emerges from indoor unit.

• Condensation effect due to cooling process.

Water flowing sound during operation.

• Refrigerant flow inside the unit.

The room has a peculiar odour.

• This may due to damp smell emitted by the wall, carpet, furniture or

clothing.

Indoor fan stops occasionally during automatic

fan speed setting.

• This helps to remove the surrounding odours.

Operation is delayed a few minutes after

restart.

• The delay is a protection to the unit’s compressor.

Outdoor unit emits water/steam.

• Condensation or evaporation occurs on pipes.

The unit operates automatically when power is

resumed after a power failure.

• It is the Auto Restart function of the unit. Operation will be restarted

automatically under the previous operation mode and airflow direction

when power is resumed as the operation is not stopped by remote control.

• To cancel the Auto Restart Control, please contact with authorized

distributor.

Power indicator blinks during operation and

the indoor fan is stopped.

• The unit is in defrost mode, and the melted frost is drained from the

outdoor unit.

Indoor fan stops occasionally during heating

operation.

• To avoid unintended cooling effect.

Power indicator blinks before the unit is

switched on.

• This is a preliminary step in preparation for the operation when the ON

timer has been set.

Cracking sound during operation.

• Changes of temperature cause the expansion/contraction of the unit.

The following symptoms do not indicate malfunction.

Check the following before calling for servicing.

The unit stops and the timer indicator blinks.

SELECT

SELECT

CHECK

CHECK ERROR

ERRORRESET

RESET RESET

RESET

SET/CANCEL

SET/CANCEL

POWERFUL / QUIET

POWERFUL / QUIET

1

Press for 5

seconds.

3

Press for 5 seconds

to quit checking.

2

Press until you hear

beep sound, then jot

down the error code.

• Turn the unit off and reveal the error code to your nearest dealer.

TROUBLESHOOTING

TROUBLESHOOTING

• The unit may be operable

(with 4 beeps) on a limited

basis, depending on the

error.

F566128-EN1.indd 7