Asus P5L 1394 User Manual

Page 48

Advertising
background image

2-28

Chapter 2: Hardware information

8. CPU and Chassis Fan connectors

(4-pin CPU_FAN, 3-pin CHA_FAN)
The fan connectors support cooling fans of 350 mA ~ 2000 mA (24 W

max.) or a total of 1 A ~ 3.48 A (41.76 W max.) at +12V. Connect the

fan cables to the fan connectors on the motherboard, making sure that

the black wire of each cable matches the ground pin of the connector.

Only the CPU_FAN connector supports the ASUS Q-Fan feature.

DO NOT forget to connect the fan cables to the fan connectors. Insufficient

air flow inside the system may damage the motherboard components.

These are not jumpers! DO NOT place jumper caps on the fan connectors!

9. Chassis intrusion connector (4-1 pin CHASSIS)

This connector is for a chassis-mounted intrusion detection sensor or

switch. Connect one end of the chassis intrusion sensor or switch cable

to this connector. The chassis intrusion sensor or switch sends a high-

level signal to this connector when a chassis component is removed or

replaced. The signal is then generated as a chassis intrusion event.
By default, the pins labeled “Chassis Signal” and “GND” are shorted

with a jumper cap. Remove the jumper caps only when you intend to

use the chassis intrusion detection feature.

P5

L

1394

R

P5L 1394 Fan Connectors

CPU_FAN

GND

CPU FAN PWR

CPU FAN IN

CPU FAN PWM

CHA_FAN

GND

Rotation

+12V

P5L

139

4

R

P5L 1394 Intrusion Connector

CHASSIS

+5VSB_M

B

Chassis Signal GND

(Default)

Advertising