Product specification – Panasonic KITUE9JKE User Manual

Page 8

Advertising
background image

56


Indoor Unit
Outdoor Unit

Test conditions

1. Cooling: Indoor Dry Bulb Temp. (°C) 27

Outdoor Dry Bulb Temp. (°C) 35

Wet Bulb Temp. (°C) 19

Wet Bulb Temp. (°C) 24

Heating: Indoor Dry Bulb Temp. (°C) 20

Outdoor Dry Bulb Temp. (°C) 7

Wet Bulb Temp. (°C) 12 (MAX)

Wet Bulb Temp. (°C) 6

2. Standard piping length: 7.5m (Includes Indoor Unit piping length).

Model

CS-UE9JKE

CU-UE9JKE

CS-UE12JKE

CU-UE12JKE

COOL

HEAT

COOL

HEAT

Single, 230V, 50Hz

Single, 230V, 50Hz

Power/Current

[kW]

0.750

0.900

1.060

1.170

[A]

3.60

4.10

4.70

5.20

Refrigerant

[kg]

R410A

0.780

R410A

0.970

Cooling Capacity

[kW]

2.500

3.500

Heating Capacity

[kW]

3.300

4.250

Noise Level

JIS C 9612

[<70 dB(A)]

[dB(A)]

42

42

42

42

Conditions

1m Distance

Max. cooling/

heating

operation

46

47

48

50

Sound power

level

[dB(A)]

53

53

53

53

59

60

61

63

Air Circulation

[m

3

/min.]

10.8

11.4

11.7

12.4

Product Weight

[kg]

7.0

8.5

28

30

Dimensions (L × W × H)

[mm]

770x205x250

799Ч183Ч280

780Ч289Ч540

780Ч289Ч540