BASIC OPERATION

OFF / ON

TO TURN ON OR OFF THE UNIT

• When unit is ON, operation LED is lit and the actual

temperature for water outlet and outdoor ambient are

shown on the control panel display.

MODE

TO SELECT OPERATION MODE

HEAT

HEAT +TANK

TANK

HEAT MODE

- To turn ON or OFF the panel/fl oor heating operation.

- In this mode, the outdoor unit will provide heating

capacity to the indoor unit.

HEAT + TANK MODE

- In this mode, the outdoor unit will provide heating

capacity to the sanitary tank and indoor unit.

- This operation is not used when the sanitary water

tank is not installed.

TANK MODE

- To turn ON or OFF the sanitary tank operation.

- In this mode, the outdoor unit will provide heating

capacity to the sanitary tank.

QUIET

TO ENJOY QUIET ENVIRONMENT

• This operation reduces outdoor unit noise. In this

condition, it may cause decrease in heating capacity.

HEATER

TO ENABLE THE BACKUP

HEATER

• The backup heater provides extra heating capacity

during cold outdoor temperature and only can operated

at heat mode operation for indoor unit when he was

enabled by pushing this button.

• The backup heater will automatically turn ON when the

setting conditions is fulfi lled.

• To disabled the Heater operation manually, press the

respective button again.

STATUS

SEARCH

CHECK

SYSTEM STATUS CHECK MODE

1. Press

CHECK

for 5 seconds to enter STATUS mode.

2. Press

or

to check the Water Inlet

Temperature, Tank Temperature, Compressor Running

Frequency or Error History.

• Press

CANCEL

to exit STATUS mode.

• Once STATUS mode is entered, “STATUS”

indicator is ON.

• STATUS mode cannot be activated when the

“SETTING” indicator is ON.

• It is strongly recommended to contact the nearest

authorized dealer to change the water temperature range.

• Using the control panel could set the temperature

range for water outlet temperature and outdoor ambient

temperature.

SYSTEM SETTING MODE

SET

SELECT

CANCEL

SETTING

TIMER

OUTDOOR

HEAT

SETTING
STATUS
PUMPDW

BOOSTER

QUIET

TANK

WATER OUTLET

C

HEATER

OPERATION

FORCE

HEATER

ACTUAL

ON

Operation Mode

Temperature display

SETTING indicator

Parameter *

1. Press

SET

for 5 seconds to enter “SETTING” mode.

“SETTING” indicator is ON.

2. Press or

to choose a parameter.

3. After selecting the desired parameter, press

SELECT

to enter

the parameter.

4. Press or

to set the desired temperature.

5. Press

SET

again to confi rm the setting.

• Repeat steps 2 to 5 to set other parameters.
Operation

Mode

Parameter * Description

HEAT

Low outdoor ambient set temperature

(-15°C ~ 15°C).

HEAT

High outdoor ambient set temperature

(-15°C ~ 15°C).

HEAT

Water outlet set temperature at low outdoor

ambient temperature (25°C ~ 55°C).

HEAT

Water outlet set temperature at high outdoor

ambient temperature (25°C ~ 55°C).

Water Temperature

Outdoor Temperature

HEAT

OFF

Set temperature for turning OFF heating

operation (5°C ~ 35°C).

HEATER

ON

Outdoor ambient set temperature for turning

ON heater operation (-15°C ~ 20°C).

TANK

Sanitary tank set temperature

(40°C ~ 75°C).

WATER TEMPERATURE THERMO SHIFT SETTING

1. Press

SET

within 5 seconds.

• Repeat steps 3 to 5 to set the desired shift temperature

(-5°C ~ 5°C).

Notes:
• Press

CANCEL

or wait 30 seconds to exit “SETTING” mode.

• The setting temperature will be stored in the system once

confi rm.

• “SETTING” mode cannot be activated when the

“PUMPDW” and “STATUS” indicator is ON.

ADVANCE OPERATION

Advertising
This manual is related to the following products: