Operation conditions

Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature

Temperature (°C)

Indoor

Outdoor

DBT

WBT

DBT

WBT

COOL

Max. 32

23

43

26

Min. 16

11

-10

-

HEAT

Max. 30

-

24

18

Min. 16

-

-15

-16

To

learn more...

Sunlight Sensor operation

Set
temperature

HEAT

COOL/DRY

+1 °C

-1 °C

-1 °C

ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.

Ambient condition

Mode

ECONAVI is activated,
the unit maintains set
temperature until a high
sunlight intensity is detected.
The sunlight sensor detects
sunlight intensity during
weather or day/night
changes, and the unit adjusts
temperature.

• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.

The human activity sensor will also scan for area of heat source and movement in a room.

Detection area

• Based on area activeness horizontal airfl ow direction louver will adjust either fi x at

predetermined position or swing left/right periodically.

7m

120º

• The human activity sensor performance is infl uenced by indoor unit location, movement speed, temperature range,

etc.

• The human activity sensor may:

- mistakenly detect an object with heat source & movement similar to human, such as pets, etc.
- mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.

• Do not place large objects near the sensor and keep away heating units or humidifi er from the sensor’s detection