Tim ing legend, Reversing timer spin/dwell adjustments – American Dryer Corp. Phase 7 OPL with S.A.F.E. Gas DSI AD-78 IV User Manual
Page 43
Advertising
39
SECTION VII
REVERSING TIMER SPIN/DWELL ADJUSTMENTS
Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left
rear area of the dryer.
Both the dwell (stop) time and the basket (tumbler) spin time are adjustable by mode selection switches located
on the electronic timer (refer to the illustration below).
TIM ING LEGEND
SPIN TIME
Adjustment Position Number
1
2
3
4
5
Time in Seconds*
30
60
90
120
150
DWELL (STOP) TIME
Adjustment Position Number
1
2
3
4
5
Time in Seconds*
5
6.3
7.6
8.9
10.2
* Values shown are +/- 1-second.