3-4. remove the indoor air temperature sensor, 3-5. remove the power box and control box – Panasonic KS12NB41A User Manual

Page 43

Advertising
background image

1

2

3

7-3-4. Remove the indoor air temperature sensor.

(1) Disconnect the connector CN08 (ROOM 2P) in the control box and remove the indoor air temperature

sensor. (Fig. 10)

7-3-5. Remove the power box and control box.

(1) Remove a screw and remove the terminal cover. (Fig. 11)

(2) Remove the 2 screws and remove the power box cover. (Fig. 11)

(3) Disconnect the power lines (No. 1 and No. 2) / signal line (No. 3) and ground cable from the terminals in

the power box. (Fig. 12)

Indoor air temperature sensor

CN08

Terminal

Fig.10

Fig.11

Fig.12

Ground cable

Terminal cover

Screw

Screw

Power box cover

Power lines / Signal line

43