Specifications – Panasonic KE12NB41 User Manual

Page 18

Advertising
background image

17

SPECIFICATIONS

Model No.

• For Single use

• For Single use

Outdoor Unit

Indoor Unit

CS-KE12NB41

CU-KE12NK1

11,900 [ 3,000 ~ 11,900 ]

47

Single-phase, 115 V, 60 Hz

3.50 [ 0.90 ~ 3.50 ]

4.00 [ 0.90 ~ 4.00 ]

13,600 [ 3,000 ~ 13,600 ]

-

49

-

21-9/16Ч28-11/32Ч10-7/16

(548Ч720Ч265)

-

34/32/31

-

35/34/32

Heating Capacity

Operation
Sound

Unit Dimensions (H×W×D)

Net Weight

Power Source

Cooling Capacity

kW

BTU/h

kW

BTU/h

inch(mm)

lbs.(kg)

Cooling

Operation

Outdoor (Hi)

Indoor(H/M/L)

Outdoor (Hi)

Indoor(H/M/L)

Heating

Operation

dB(A)

dB(A)

77.2(35.0)

11-5/32Ч22-5/8Ч22-5/8

(283Ч575Ч575)

35.3(16.0)

Model No.

Outdoor Unit

Indoor Unit

CS-KE18NB4UW

CU-KE18NKU

17,500 [ 4,000 ~ 17,500 ]

51

Single-phase, 208-230 V, 60 Hz

5.15 [ 1.20 ~ 5.15 ]

6.00 [ 1.30 ~ 6.00 ]

20,400 [ 4,400 ~ 20,400 ]

-

52

26-3/8Ч34-21/32Ч11-7/32

(670Ч880Ч285)

-

44/40/36

-

44/40/36

Heating Capacity

Operation
Sound

Unit Dimensions (H×W×D)
(Indoor unit : Include panel)

Net Weight

Power Source

Cooling Capacity

kW

BTU/h

kW

BTU/h

inch(mm)

inch(mm)

lbs.(kg)

Cooling

Operation

Outdoor (Hi)

Indoor(H/M/L)

Outdoor (Hi)

Indoor(H/M/L)

Heating

Operation

dB(A)

dB(A)

97.0(44.0)

11-5/32Ч22-5/8Ч22-5/8

(283Ч575Ч575)

35.3(16.0)

-

Model No.

Ceiling Panel

CZ-18BT1U

6.0(2.7)

1-9/16Ч24-19/32Ч24-19/32

(40Ч625Ч625)

Unit Dimensions (H×W×D)

Net Weight

lbs. (kg)

Advertising