19

2. Electrical Service Specifications

a. Gas Models

IMPORTANT: Figures shown are for Non-Reversing Models ONLY. For reversing models contact

the factory.

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is

affixed to the back of the dryer, at the upper right hand corner. In the case of
208 VAC or 230/240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.

IMPORTANT: The wire size must be properly sized to handle the related current.

WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME. Any damage done to dryer

components due to improper voltage connections will automatically VOID THE
WARRANTY.

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or

obligation.

ADG-758 (Gas)

E

LEC TRIC AL

S

ERVIC E

S

PEC IFIC ATIONS

(

P ER DRYER

)*

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

CIRCUIT

BREAKER

60 Hz

50 Hz

120

1 ш

2

12

--

25

208

1 ш

2

7

--

1 5

240

1 ш

2

7

4

1 5

208

3

3

- -

1 5

240

3

3

3

1 5

380/400

3/4

--

2

1 5

416

3/4

--

2

1 5

460/480

3/4

2

--

1 5

* Contact factory for electrical information not listed.