Typical recess installation, Typical pier type installation – American Standard Cadet Elite 2772E SERIES User Manual

Page 2

Advertising
background image

1486mm

(58-1/2)

CUTOUT

TYPICAL RECESS INSTALLATION

LEVELING
SURFACE

WATERPROOF
SEALANT

BATH

WHIRLPOOL ONLY:

UNLESS AN ACCESS OPENING OF AT LEAST

12" X 24" (305 X 610MM) IS PROVIDED,

WARRANTY SERVICE WILL NOT BE PERFORMED.

TYPICAL PIER TYPE INSTALLATION

A S D E S I R E D

1029mm

(40-1/2)

CUTOUT

A S D E S I R E D

464mm

(18-1/4)

ACCESS PANEL

610mm

(24)

305mm

(12)

610mm

(24)

305mm

(12)

464mm

(18-1/4)

464mm

(18-1/4)

1527mm

(60-1/8)

1029mm

(40-1/2)

1067mm

(42)

TUB WIDTH

L E V E L I N G
S T R I N G E R S

WHIRLPOOL ONLY:

UNLESS AN ACCESS OPENING OF AT LEAST

12" X 24" (305 X 610MM) IS PROVIDED,

WARRANTY SERVICE WILL NOT BE PERFORMED.

INSTALLATION AND FRAMING INSTRUCTIONS

The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs
as required. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an
access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for
access to the drain components.

NOTE: The apron should not be used as the primary access opening.

1. Position the whirlpool into the installation opening and level the deck, shimming the integral support feet as necessary.

Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1).

2. Remove the whirlpool and attach a 2 x 4 stringer to the studs, with the top of the stringer touching the traced line.

3. Install drain components to the whirlpool following the manufacturers instructions. Before replacing your whirlpool for final

installation, be certain that an opening has been provided in the sub-floor for the drain. See the roughing-in drawing for
suggested opening size and location dimensions.

4. Replace whirlpool and re-shim the integral support feet, shimming the entire length of the support feet. Secure the shims

using construction adhesive, silicone, mortar or equivalent materials. While not a necessity, the use of a foundation base
consisting of cement (e.g. Sakrete), mortar, or grout will help provide a solid and secure installation.

752861-100 Rev. D (2)

TILE

TILE

BEAD

STRIP

LEVELING

STRINGER

BATH

ADHESIVE

SEALANT

WALLBOARD

NOTE: Tile bead kit not included and must be
purchased separately.

FIG. 1

Advertising